Morphometric Study of the Optic Nerve Head Among Northern Nigerian Adults, Using Optical Coherence Tomography

  • Home
  • Morphometric Study of the Optic Nerve Head Among Northern Nigerian Adults, Using Optical Coherence Tomography

Morphometric Study of the Optic Nerve Head Among Northern Nigerian Adults, Using Optical Coherence Tomography

1*Nuraddeen Jaafar Ibrahim, 1Sanusi Muhammad Bello, 2Prashanth Kumar Katta, 1Tarig Hussain Abdelrahman, 3Sadiq Hassan, 3Saudat Garba Habib
1Department of Biomedical Sciences, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia
2Department of Restorative Dental Sciences, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia
3Department of Ophthalmology, Faculty of Clinical Sciences, College of Health Sciences, Bayero University Kano, Kano, Nigeria

ABSTRACT

Glaucoma is a common health problem worldwide especially in adult population. It is characterised by progressive irreversible optic nerve head (ONH) damage, due to alterations in retinal ganglion cells nutrition and viability. Early diagnosis is key to better management and prognosis. This study measures the ONH parameters among adults in northern Nigeria, using Optical coherence tomography (OCT). This would provide a reference values of ONH parameters that would help clinicians observe early abnormal optic nerve changes for early diagnosis of glaucoma among the population. Healthy 770 adult volunteers from ethnic northern Nigerians underwent complete ocular examination, including anterior and posterior segment examination. Those with normal findings proceeded to have optic nerve head examination using a Stratus OCT machine. The ONH parameters analysed were; optic disc area (DA), rim area (RA), cup area (CA), and cup-to-disc ratio (CDR). The mean DA, RA, and CDR found in the study were 2.35mm2 SD=+0.88, 1.76mm2 SD=+0.43, and 0.44 SD=+0.21, respectively. The DA and CDR were significantly larger with age (p=0.001) and the RA was found to significantly decline with age. A regression formula was derived to use for the estimation of ONH dimensions based on age. This study provided reference values of the ONH parameters among the northern Nigerians. We also obtained a regression model that could be used to estimate different ONH dimensions from individual’s age, with a reliable accuracy. This would enable an ethnic specific screening protocol for clinicians in screening, diagnosis, and management of optic neuropathies like glaucoma.

KEYWORDS

Optic nerve head, Optical Coherence Tomography, Disc area, Cup-disc ratio, rim area, Cup area, Glaucoma.


REFERENCES

1) Wang YX, Panda-Jonas S, Jonas JB. Optic nerve head anatomy in myopia and glaucoma, including parapapillary zones alpha, beta, gamma and delta: Histology and clinical features. Prog Retin Eye Res 2021;83: 100933
2) Tharwat HM, Amal ME, Hossanti ES. Retinal Nerve Fibre Layer vs Optic Nerve Head Evaluation in Diagnosis of Glaucoma and Suspects. Journal of the Egyptian Ophthalmological Society 2013;103: 253-258.
3) Lawan A, Rabi YS, Phillips A. Macular Volume and Central Foveal Thickness Measurements in Normal Eyes of Healthy Nigerian Adults Using Optical Coherence Tomography. Annals of Afr Med 2014;13: 134- 137.
4) Jonas JB, Thomas R, George R, Berenshtein E, Muliyil J. Optic disc morphology in south India: the Vellore Eye Study. Br J Ophthalmol 2003;87(2):189-96
5) Pitkänen J, Liinamaa J, Leiviskä I, Saarela V. Morphology of the optic nerve head and factors affecting it in the Northern Finland birth cohort. Acta Ophthalmologica 2023;101:575–581
6) Barbara CM, Louis BC, Darrel W, Joni H, Jennifer L, Budenz D, et al. Optic Nerve Head Topographic Analysis in Normal Subjects: Correlation to Disc Size, Age and Ethnicity. Journal of Glaucoma 2010;19(5):310-318.
7) Li D, Rauscher FG, Choi EY, Wang M, Baniasadi N, Wirkner K, et al. Sex-Specific Differences in Circumpapillary Retinal Nerve Fiber Layer Thickness. Ophthalmology 2019;127(3):357-368.
8) Hermann MM, Theofylaktopoulos I, Bangard N, Junecu-Cuypers C, Coburgar S, Dielteshorst M. Optic Nerve Head morphometry in Healthy Adults using confocal scanning tomography. British Journal of ophthalmology 2004;88 (6): 761-5,
9) Samaravickrama C, Hong T, Jonas JB, Mithell P. Measurement of Optic Nerve Head Parameters. Survey of Ophthalmology 2012;57(4):317-36
10) Knight OJ, Girkin CA, Budenz DL, Durbin MK, Feuer WJ. Cirrus OCT Normative Database Study Group. Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT. Arch Ophthalmol 2012;130(3):312-8.
11) Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R Jr, Weinreb RN et al. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol 2005;139(1):44-55.
12) Muna B, Sharan S, Mohana K, Ramya S. Optical coherence Tomography, A guide to interpretation of Common Macular diseases. Indian Journal of Ophthalmol 2018;66(3): 485
13) Mathis T, Rosier L, Meniai F, Baillif S, Maschi C, Herault J, et al. The Lens Opacities Classification System III Grading in Irradiated Uveal Melanomas to Characterize Proton Therapy-Induced Cataracts. Am J Ophthalmol. 2019; 201:63-71.
14) Mansoori T, Viswanath K, Balakrishna N. Optic disc topography in normal Indian eyes using spectral domain optical coherence tomography. Indian J Ophthalmol. 2011;59(1):23-7.
15) Dacosta S, Bilal S, Rajendran B, Janakiraman P. Optic disc topography of normal Indian eyes: an assessment using optical coherence tomography. Indian J Ophthalmol 2008;56:99-102.
16) Mwanza JC, Oakley JD, Budenz L, Anderson DR. Cirrus Optical Coherence Tomography Normative Database Study Group. Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes,” Ophthalmology 2011;118:241-8.
17) Knight OJ, Girkin CA, Bundenz DL, Durbin MK, Feuer WJ. Effect of age, Race and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fibre by Cirrus OCT. Archives of Ophthalmology 2012;130:312-318
18) Gherghel D, Orgul S, Prunte C, Gugleta K, Lubeck P, Gekkieva M. Intraocular Difference in Optic Disc Topography Parametres in Normal Subjects. Current eye Research 2000;20 (4): 276- 282
19) Tariq YM, Li H, Burlutsky G. Retinal Nerve Fibre Layer and Optic Nerve Head Measurements by Spectral OCT. Eye 2012; 26:1563-1570
20) Sawada Y, Ishikawa M, Sato N, Yoshitomi T. Optic Nerve Head Morphology Assessed by Laser Scanning Tomography in Normal Japanese Subjects. Journal of Glaucoma 2011;20: 445-451.
21) Hakan D, Iclal Y, Yusuf A, Zeki BM. Assessment of ONH Topographic Parameters with CSLO. Clinical and Experl Ophthalmol 2004;32:259-264. 
22) Ramrattan RS, Wolfs RC, Jonas JB. Determinants of optic disc characteristics in a general population: The Rotterdam Study. Ophthalmology. 1999; 106:1588–96.
23) Mansoor AM. Racial variation of optic disc size.” Ophthalmic Res. 1991;23(2):67-72.
24) Sample PA, Girkin A, Zangwill LM, Jain S, Racette L, Becerra M, Weinreb N, et al. African Descent and Glaucoma Evaluation Study Group. The African Descent and Glaucoma Evaluation Study (ADAGES): design and baseline data. Arch Ophthalmol. 2009;127(9):1136-45.
25) Chi T, Ritch R, Stickler D, Pitman B, Tsai C. Racial differences in ONH parameters. Arch Ophthalmol. 1989;107(6):836-9.
26) Tsai CS, Zangwill L, Gonzalez C, Irak, I, Garden V, Hoffman R. Ethnic Differences in Optic Nerve Head Topography.” Journal of Glaucoma 1995; 4:248–257.
27) Ong LS, Mitchell P, Healey, PR, Cumming RG. Asymmetry in Optic Disc Parameters: The Blue Mountains Eye Study. Investigative Ophthalmology and Vision Science 1999; 40:849–57.
28) Kashiwagi K, Tamura M, Abe K, Kogure S. The Influence of Age, Gender, Refractive Error, and Optic Disc Size on the Optic Disc Configuration in Japanese Normal Eyes. Acta Ophthalmol Scand 2000;78:200 –203.
29) Bourne RR, Foster PJ, Bunce C, Peton T, Hitchings RA, Khaw PT, Garway D. The Morphology of the Optic Nerve Head in the Singaporean Chinese population – the Tanjong Pagar Study. British Jour of Ophthalmol 2008; 92(3):303-309
30) Gvozdenović R, Risović D, Marjanović I, Vuković D, Stanković B. Morphometric characteristics of optic disc in patients with myopia and primary open-angle glaucoma. Vojnosanit Pregl 2013;70(1):51-56.
31) Jonas, JB, Schmidt AM, Muller-Bergh JA, Schlotzer-Schrehardt UM Naumann GO. Human Optic Nerve Fiber Count and Optic Disc Size. Investigative Ophthalmology and Vision Science1992; 33:2012–8.
32) Budenz DL, Anderson DR, Varma R, Schuman J, Cantor L, Savell J, Greenfield DS, Patella VM, Quigley HA, Tielsch J. Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. Ophthalmology 2008;114(6):1046-52.
33) Preussner PR, Grossmann A, Ngounou F, Kouogan G, Tamon J. Glaucoma screening in Western Cameroon. Graefes Arch Clin Exp Ophthalmol 2009;247(12):1671-5.

  • Share

Leave a Reply

Your email address will not be published. Required fields are marked *